Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Frontiers of Medicine ; (4): 143-155, 2023.
Article in English | WPRIM | ID: wpr-971621

ABSTRACT

Gliomas are the most common central nervous system tumours; they are highly aggressive and have a poor prognosis. RGS16 belongs to the regulator of G-protein signalling (RGS) protein family, which plays an important role in promoting various cancers, such as breast cancer, pancreatic cancer, and colorectal cancer. Moreover, previous studies confirmed that let-7c-5p, a well-known microRNA, can act as a tumour suppressor to regulate the progression of various tumours by inhibiting the expression of its target genes. However, whether RGS16 can promote the progression of glioma and whether it is regulated by miR let-7c-5p are still unknown. Here, we confirmed that RGS16 is upregulated in glioma tissues and that high expression of RGS16 is associated with poor survival. Ectopic deletion of RGS16 significantly suppressed glioma cell proliferation and migration both in vitro and in vivo. Moreover, RGS16 was validated as a direct target gene of miR let-7c-5p. The overexpression of miR let-7c-5p obviously downregulated the expression of RGS16, and knocking down miR let-7c-5p had the opposite effect. Thus, we suggest that the suppression of RGS16 by miR let-7c-5p can promote glioma progression and may serve as a potential prognostic biomarker and therapeutic target in glioma.


Subject(s)
Humans , Phosphatidylinositol 3-Kinases/metabolism , Proto-Oncogene Proteins c-akt/metabolism , MicroRNAs/metabolism , Glioma/genetics , Genes, Tumor Suppressor , Cell Proliferation , Gene Expression Regulation, Neoplastic , Cell Line, Tumor
2.
Chinese Journal of Medical Instrumentation ; (6): 450-453, 2021.
Article in Chinese | WPRIM | ID: wpr-888644

ABSTRACT

OBJECTIVE@#The patient monitors were used to explore the alarm fatigue in a cardiac care unit and to investigate the awareness and reaction of nurse to alarms.@*METHODS@#A semi-structured survey was taken to acquire nurses' feeling and knowledge about monitoring alarm. Three full-time researchers were scheduled to track the alarms with annotations, and analyze the alarm data of 12 patient monitors using central monitoring system.@*RESULTS@#A total of 72 310 unique alarms occurred in the 67-day study period. About 75.7% of them were physiological alarms and less than 10% of medium-low alarms were false positives. The average alarm rate was 128 alarms/patient-day.@*CONCLUSIONS@#There remains alarm fatigue in CCU, the alarm accuracy has improved than the past by applying new technologies. In some cases, clinicians will pay more attention to trend alarm and combination alarm.


Subject(s)
Humans , Arrhythmias, Cardiac , Clinical Alarms , Electrocardiography , Monitoring, Physiologic , Surveys and Questionnaires
3.
Journal of Medical Biomechanics ; (6): E186-E192, 2019.
Article in Chinese | WPRIM | ID: wpr-802491

ABSTRACT

Objective Aiming at solving the problems of pain on the anteromedial tibia, tibial component loosening and osteoarthritis progression after unicompartmental knee arthroplasty (UKA), the influence of different geometric shapes of tibial component pegs on stress distributions in tibia was analyzed by finite element method. Methods The finite element models with UKA were established and validated. Geometric shapes of tibial component were designed. Under the same loading condition, the tibial components with double-peg, single-keel, double-keel and cross-star were studied for finite element analysis and compared with intact model, so as to evaluate the influence of tibial component with different shapes on stresses of cortical bone in anteromedial tibia, cancellous bone under tibial component and cartilage in contralateral tibia. Results Compared with the intact model, the peak stress of cortical bone in anteromedial tibia with double-peg, single-keel, double-keel and cross-star tibial components increased by 56.1%, 55.9%, 54.5% and 68-4%, respectively. The peak stress of cancellous bone under tibial component with single-keel and double-keels decreased by 8.1% and 15.6% respectively, while the peak stress of cancellous bone under tibial component with double-peg and cross-star increased by 67-9% and 121-5%, which were higher than the fatigue yield stress of cancellous bone. The peak stress of cartilage in contralateral tibia with double-peg, single-keel, double-keel and cross-star tibial components decreased by 42.1%, 26.6%, 24.2% and 28.5%, respectively. ConclusionsThe load distribution of the medial and lateral tibia changed after UKA operation, and a greater load was observed on the replacement side. Single-keel and double-keel tibial components were more effective in reducing stresses on cortical bone in anteromedial tibia and cancellous bone, while the stress distribution in tibia with single-keel tibial component was closer to that of the intact tibia. The research findings can provide theoretical references for designing single-keel tibial component of unicompartmental knee prosthesis which conforms to better mechanical properties of the knee joint.

4.
Journal of Medical Biomechanics ; (6): E417-E424, 2019.
Article in Chinese | WPRIM | ID: wpr-802476

ABSTRACT

Objective To measure and investigate the anatomical characteristics of the proximal femur canal curves in patients with developmental dysplasia of the hip (DDH), and to provide references for the design of femoral stem of DDH patients. Methods Three-dimensional reconstructions of the proximal femur were conducted from the CT data, and the anatomical morphology characteristics were obtained from 64 patients with DDH (74 hips, 12 males, 52 females, average age of 45.3 years) and 30 healthy controls (30 hips, 21 males, 9 females, average age of 29.4 years). Multiple anteroposterior diameter and mediolateral diameter around the lesser trochanter at different heights and the fitting curves of different groups were obtained. Results The femoral neck anteversion angle, neck-shaft angle, height of the isthmus, canal flare index (CFI), femoral head diameter and femoral offset of DDH patients and healthy controls were 26.39°±14.74° and 15.68°±7.95°, 125.65°±5.73° and 129.19°±5.80°, (99.14±14.62) mm and (110.13±11.73) mm, 3.63±0.77 and 4.45±0.79, (44.01±5.75) mm and (47.26±3.94) mm, (31.80±3.82) mm and (36.42±4.84) mm, respectively. DDH group had the significantly greater femoral neck anteversion angle, and other anatomical morphology characteristics were significantly smaller than the control group. The obtained anteroposterior diameter, mediolateral diameter and the fitting curves showed that DDH group had narrow medullary cavity and forward shifting anteroposterior diameter. In addition, there was a statistical significance between the Crowe Ⅳ DDH and other types of DDH, and deformation degree of the femur increased with the increase of DDH type. Conclusions The proximal femur of DDH patients was significantly different from the healthy controls. Moreover, there were significantly morphological differences between different types of DDH. The research findings can be used as quantitative references for understanding the morphological feature of DDH patients and the corresponding design of femoral stem for DDH patients.

5.
Journal of Medical Biomechanics ; (6): E417-E424, 2019.
Article in Chinese | WPRIM | ID: wpr-802373

ABSTRACT

Objective To measure and investigate the anatomical characteristics of the proximal femur canal curves in patients with developmental dysplasia of the hip (DDH), and to provide references for the design of femoral stem of DDH patients. Methods Three-dimensional reconstructions of the proximal femur were conducted from the CT data, and the anatomical morphology characteristics were obtained from 64 patients with DDH (74 hips, 12 males, 52 females, average age of 45.3 years) and 30 healthy controls (30 hips, 21 males, 9 females, average age of 29.4 years). Multiple anteroposterior diameter and mediolateral diameter around the lesser trochanter at different heights and the fitting curves of different groups were obtained. Results The femoral neck anteversion angle, neck-shaft angle, height of the isthmus, canal flare index (CFI), femoral head diameter and femoral offset of DDH patients and healthy controls were 26.39°±14.74° and 15.68°±7.95°, 125.65°±5.73° and 129.19°±5.80°, (99.14±14.62) mm and (110.13±11.73) mm, 3.63±0.77 and 4.45±0.79, (44.01±5.75) mm and (47.26±3.94) mm, (31.80±3.82) mm and (36.42±4.84) mm, respectively. DDH group had the significantly greater femoral neck anteversion angle, and other anatomical morphology characteristics were significantly smaller than the control group. The obtained anteroposterior diameter, mediolateral diameter and the fitting curves showed that DDH group had narrow medullary cavity and forward shifting anteroposterior diameter. In addition, there was a statistical significance between the Crowe Ⅳ DDH and other types of DDH, and deformation degree of the femur increased with the increase of DDH type. Conclusions The proximal femur of DDH patients was significantly different from the healthy controls. Moreover, there were significantly morphological differences between different types of DDH. The research findings can be used as quantitative references for understanding the morphological feature of DDH patients and the corresponding design of femoral stem for DDH patients.

6.
Journal of Medical Biomechanics ; (6): E001-E005, 2018.
Article in Chinese | WPRIM | ID: wpr-803756

ABSTRACT

Objective To compare biomechanical properties between the anatomical clavicle plate and the reconstructed clavicle plate, and investigate the influence of pre-bending or repeated bending process on biomechanical properties of the reconstructed clavicle plate, so as to provide biomechanical evidence for treating midshaft clavicle fracture in clinic. Methods The reconstructed clavicle plate was bent by 1, 2, 3, 5 times respectively based on shape of the anatomical clavicle plate. The biomechanical differences in anatomical plate group, reconstructed plate group and pre-bending plate group were compared by static compression test. Results The fixation stiffness and strength of the anatomical plate were better than those of the reconstructed plate. There was no significant difference in stiffness and strength between the anatomical plate group and one-time bending group. Pre-bending had a great effect on mechanical properties of the clavicle plate, and stiffness and strength of the clavicle plate were obviously improved after one-time bending. The mechanical properties of the clavicle plate were obviously reduced by bending of the clavicle plate after one-time bending. Conclusions The stiffness and strength of the anatomical plate and one-time bending plate are higher than those of the normal reconstructed plate. It is recommended that surgeons should perform bending appropriately according to the patient’s clavicle anatomy when using the reconstructed clavicle plate for fracture fixation, and minimize the number of repeated bending to maintain stiffness and strength of the clavicle plate.

7.
China Pharmacy ; (12): 3169-3174, 2017.
Article in Chinese | WPRIM | ID: wpr-612263

ABSTRACT

OBJECTIVE:To investigate the expression difference and its mechanism of miR-27a-3p and HOXB8 protein in cer-vical cancer tissues of HPV16-positive and HPV16-negative patients. METHODS:A total of 120 patients with cervical cancer in our hospital during Jan. 2012-Jan. 2016 were divided into HPV16-positive group(60 cases)and HPV16-negative group(60 cases) according to HPV16 infection situation. The expression of miR-27a-3p mRNA and HOXB8 mRNA in cervical cancer tissue were de-tected by RT-qPCR. The expression of HOXB8 protein was detected by Western blotting assay. DNA methylation level of miR-27a-3p promoter region was detected by nested-down methylation specific PCR (nMS-PCR). Histone methylation level of miR-27a-3p promoter region was detected by chromatin immunoprecipitation PCR (CHIP-PCR). The expression of miR-27a-3p mRNA and HOXB8 mRNA were detected after transfecting miR-27a-3p mimic and inhibitor into Human cervical cancer cell line SiHa,respectively. RESULTS:The expression of miR-27a-3p in HPV16-positive group was significantly lower than HPV16-nega-tive group,while HOXB8 mRNA and protein expression,DNA and histone methylation levels of miR-27a-3p promoter region were significantly higher than HPV16-negative group,with statistical significance (P<0.05 or P<0.01). After transfecting miR-27a-3p mimic into SiHa cells,the expression of miR-27a-3p was increased significantly,while that of HOXB8 mRNA was de-creased significantly;after miR-27a-3p inhibitor transfection,the expression of miR-27a-3p was decreased significantly,while that of HOXB8 mRNA was increased significantly,with statistical significance(P<0.01). CONCLUSIONS:HPV16 may down-regu-late the expression of miR-27a-3p through DNA methylation and histone methylation of promoter region,so as to influence the gen-eration and development of cervical cancer. HOXB8 may be the target protein of miR-27a-3p.

SELECTION OF CITATIONS
SEARCH DETAIL